Convention: All wall elevations are interior views (seen from inside the room looking at the wall). Ceiling views are reflected ceiling plans (RCP, looking up). Floor views are plan views (looking down). All heights from Finished Floor Level (AFF). Acoustic ceiling height = 2.75 m in all rooms.

Comprehensive Elevations

6-surface interior views for all 4 rooms — walls, ceiling RCP, floor build-up. Every surface documented with acoustic treatments, MEP penetrations, and material specifications from SSOT via DXF.

LEGEND: Absorption panel Bass trap QRD diffuser Acoustic door Window OW-1 Ceiling/Floor zone
VO Live Room — 6-Surface Elevation Set

Surfaces 1–4: Wall Elevations Walls

VO Live — North wall B304 · 327×275cm · IDU-04 HVAC · 4 absorption panels · DXF verified Apr 7 2026 W ← (facing north: left=west, right=east) → E CEILING 2.75m FLOOR IDU-04 duct 1200×600 1200×600 1200×600 1200×600 327 cm 275 cm Panel positions approximate — exact layout computed by wall_layout.py. IDU-04 duct penetration at top per HVAC schedule. Bass trap (all 4 corners) Absorption panel 1200×600mm IDU-04 HVAC unit
North Wall
IDU-04 mounted on this wall (dedicated unit). Fresh air duct penetration for Run A supply. 1500mm inline silencer feeds 2 fresh air terminals.
VO Live — South wall (W6) B304 · 275×275cm · shared wall with Control Room · DXF verified Apr 7 2026 E ← (facing south: left=east, right=west) → W CEILING 2.75m FLOOR D3 STC 45 80×220cm → Control Room OW-1 STC 50 / 80×55cm 64cm from E ← → 180cm from E 275 cm 275 cm No panels on south wall — D3+OW-1+corner zones use all available space. 8 panels on N/E/W walls. Bass trap RWA45 (all 4 corners) OW-1 observation window Acoustic door D3
South Wall
No duct penetrations. Acoustic panel treatments per SSOT schedule. SW corner bass trap omitted — D3 door occupies this corner. Door frame perimeter seal provides equivalent low-frequency isolation.
VO Live — East wall B304 · 176×275cm · no openings · 2 absorption panels · DXF verified Apr 7 2026 S ← (facing east: left=south, right=north) → N CEILING 2.75m FLOOR 1200×600 1200×600 176 cm 275 cm Portrait wall (176cm wide). Panel positions approximate — wall_layout.py computes exact. Bass trap (all 4 corners) Absorption panels
East Wall
No duct penetrations on this wall.
VO Live — West wall B304 · ~176×275cm · NW diagonal cutoff · needs DXF confirmation · Apr 7 2026 N ← (facing west: left=north, right=south) → S diagonal NW wall CEILING 2.75m FLOOR diagonal 1200×600 1200×600 ~176 cm (approx) 275 cm ⚠ West wall has NW diagonal cutoff. Exact geometry needs DXF confirmation from architect. Bass trap (3 corners — NW blocked) Panels (approximate)
West Wall
No duct penetrations on this wall.

Surface 5: Ceiling — Reflected Ceiling Plan RCP

Tile: Rockfon Sonar E NRC 0.90  |  Ceiling height: 275cm AFF [AC]

IDU-04 FA FA Run A (1500mm sil.) 200W LED 275–327 cm (trapezoid) 176 cm NORTH ceiling height 275cm AFF [AC]

Ceiling Build-Up (Cross-Section)

Structural slab 340cm from FFL Services zone 37 cm ducts Duct zone 25 cm Insulation Rockwool ProRox 10 cm T-grid + tile 5 cm Room Interior — 275 cm AFF Interior 275 cm Plenum 50cm

Surface 6: Floor Build-Up Floor

Finish: Vinyl  |  Total raised floor: 15cm [AC]

Structural slab Sylomer SR28 28 kg/m3 18mm T&G ply — bottom bottom layer staggered joints (offset 400mm) 18mm T&G ply — top top layer Vinyl finish 25mm PERIMETER GAP — MUST NOT BRIDGE [AC] Total build-up: 15 cm [AC]

Floor Plan View

25 mm perimeter gap (red dashed) VINYL FLOORING No floor box in this room 275–327 cm x 176 cm
Control Room — 6-Surface Elevation Set

Surfaces 1–4: Wall Elevations Walls

Control Room — North wall (W6) B311 · 275 × 275 cm · shared wall with VO Live · DXF verified Apr 7 2026 W ← → E W ← CEILING 2.75m FLOOR OW-1 STC 50 / 80×55cm D3 STC 45 80×220cm 275 cm 275 cm ← 15cm → ← 131cm from W → Bass trap (RWA45) OW-1 observation window Acoustic door
North Wall
IDU-03 mounted on this wall (shared with Editing via crossover duct). Run B1 branch (500mm silencer) penetration for 2 fresh air terminals.
Control Room — South wall B311 · 275 × 275 cm · 2 QRD diffusers centered · NC-18 · DXF verified Apr 7 2026 CEILING 2.75m FLOOR QRD-1 800×800mm QRD-2 800×800mm centered 275 cm 275 cm Bass trap (RWA45) QRD diffuser 800×800mm (South wall per SSOT)
South Wall
No duct penetrations. Acoustic treatment panels per SSOT schedule.
Control Room — East wall B311 · 225×275cm · D2 exit to buffer · ceiling cloud at SE (bass trap compensation) · Apr 7 2026 N ← (facing east: left=north, right=south) → S CEILING 2.75m FLOOR CEILING CLOUD 600×300mm ↓ SE trap compensated omitted → cloud D2 STC 45 90×220cm exit to buffer 1200×600 (portrait) 225 cm 275 cm SE corner trap omitted — D2 door frame 15cm from south wall. Ceiling cloud (600×300mm mineral wool) mounted at ceiling above SE corner. Cloud sits above door frame (door 220cm, cloud starts at 245cm AFF). Bass trap (3 corners) Ceiling cloud — bass trap compensation at SE corner Absorption panel Acoustic door D2
East Wall
No duct penetrations on this wall.
Control Room — West wall B311 · 225 × 275 cm · 1 absorption panel · no openings · DXF verified Apr 7 2026 CEILING 2.75m FLOOR 1200×600 landscape 225 cm 275 cm Bass trap (RWA45 corner) Absorption panel 1200×600mm
West Wall
No duct penetrations on this wall.

Surface 5: Ceiling — Reflected Ceiling Plan RCP

Tile: Rockfon Sonar E NRC 0.90  |  Ceiling height: 275cm AFF [AC]

IDU-03 FA FA Run B1 (500mm sil.) 40W LED plenum barrier at partition NORTH 225 cm 207–275 cm (trapezoid)

Ceiling Build-Up (Cross-Section)

Structural slab 340cm from FFL Services zone 37 cm ducts Duct zone 25 cm Insulation Rockwool ProRox 10 cm T-grid + tile 5 cm Room Interior — 275 cm AFF Interior 275 cm Plenum 50cm

Surface 6: Floor Build-Up Floor

Finish: Carpet  |  Total raised floor: 15cm [AC]

Structural slab Sylomer SR28 28 kg/m3 18mm T&G ply — bottom bottom layer staggered joints (offset 400mm) 18mm T&G ply — top top layer Carpet finish 25mm PERIMETER GAP — MUST NOT BRIDGE [AC] Total build-up: 15 cm [AC]

Floor Plan View

25 mm perimeter gap (red dashed) CARPET FLOORING CR-FB floor box under desk 207–275 cm x 225 cm
Video Studio — 6-Surface Elevation Set

Surfaces 1–4: Wall Elevations Walls

Video Studio — North wall B312-1 · 490×275cm · IDU-05 · 2 QRD + 3 panels · DXF verified Apr 7 2026 W ← (facing north: left=west, right=east) → E CEILING 2.75m FLOOR IDU-05 1200×600 1200×600 1200×600 QRD-1 QRD-2 490 cm 275 cm Bass trap Absorption panel 1200×600mm QRD diffuser 800×800mm IDU-05 HVAC unit
North Wall
IDU-05 mounted on this wall (dedicated unit). Run C (1000mm silencer) penetration for 2 fresh air terminals.
Video Studio — South wall B312-1 · 490×275cm · D4 UPGRADED STC48 · ceiling cloud at SW corner · DXF verified Apr 7 2026 E ← (facing south: left=east, right=west) → W CEILING 2.75m FLOOR CEILING CLOUD 1200×300mm omitted → cloud STC 40 → 48 UPGRADED D4 STC 48 (upgraded) 90×220cm 385cm from E · 15cm from W 490 cm 275 cm SW corner trap omitted — D4 frame 15cm from west wall. Ceiling cloud (1200×300mm mineral wool, charcoal fabric) mounted at ceiling above SW zone. Cloud bottom at 245cm AFF — clears door frame top (220cm AFF). Contractor note: D4 spec is STC 48, NOT STC 40. Bass trap (3 corners — SW blocked) Ceiling cloud 1200×300mm — SW corner bass trap compensation D4 acoustic door (UPGRADED STC 48 — not STC 40)
South Wall
No duct penetrations. Acoustic treatment panels per SSOT schedule.
Video Studio — East wall B312-1 · 176×275cm · MOTORIZED GREEN SCREEN · camera shoots west→east · DXF verified Apr 7 2026 S ← (facing east: left=south, right=north) → N CEILING 2.75m FLOOR MOTORIZED GREEN SCREEN HOUSING CTL GREEN SCREEN Motorized · 150×220cm deployed Chromakey fabric · RAL 6018 Electric motor, silent operation ← camera shoots west→east ▼ screen deploys down from housing screen bottom (retracted stops here) 176 cm 275 cm East wall = green screen wall. Camera on west wall shoots east. No absorption panels on this wall (screen occupies full face). Bass traps at all 4 corners (corners clear of screen housing). Bass trap (all 4 corners) Motorized screen housing (ceiling) Green screen (deployed)
East Wall
No duct penetrations on this wall.
Video Studio — West wall B312-1 · 229×275cm · no openings · 2 absorption panels · DXF verified Apr 7 2026 N ← (facing west: left=north, right=south) → S CEILING 2.75m FLOOR 1200×600 1200×600 229 cm 275 cm Bass trap (all 4 corners) Absorption panels (approx)
West Wall
No duct penetrations on this wall.

Surface 5: Ceiling — Reflected Ceiling Plan RCP

Tile: Rockfon Sonar E NRC 0.90  |  Ceiling height: 275cm AFF [AC]

IDU-05 FA FA Run C (1000mm sil.) 200W LED plenum barrier at partition NORTH 229 cm 490 cm

Ceiling Build-Up (Cross-Section)

Structural slab 340cm from FFL Services zone 37 cm ducts Duct zone 25 cm Insulation Rockwool ProRox 10 cm T-grid + tile 5 cm Room Interior — 275 cm AFF Interior 275 cm Plenum 50cm

Surface 6: Floor Build-Up Floor

Finish: Vinyl  |  Total raised floor: 15cm [AC]

Structural slab Sylomer SR28 28 kg/m3 18mm T&G ply — bottom bottom layer staggered joints (offset 400mm) 18mm T&G ply — top top layer Vinyl finish 25mm PERIMETER GAP — MUST NOT BRIDGE [AC] Total build-up: 15 cm [AC]

Floor Plan View

25 mm perimeter gap (red dashed) VINYL FLOORING ST-FB floor box 490 cm x 229 cm
Editing Suite — 6-Surface Elevation Set

Surfaces 1–4: Wall Elevations Walls

Editing Suite — North wall B312-2 · 490×275cm · no openings · no corner traps · 4 panels · DXF verified Apr 7 2026 CEILING 2.75m FLOOR no trap no trap 1200×600 1200×600 1200×600 490 cm 275 cm Editing Suite bass traps: SW+SE corners ONLY (not NW/NE). North wall has no corner traps per SSOT acoustic schedule.
North Wall
IDU-03 serves this room via crossover duct from Control Room. Run B2 branch (300mm silencer) penetration for 2 fresh air terminals.
Editing Suite — South wall B312-2 · 490×275cm · D1 STC50 · SW+SE bass traps · DXF verified Apr 7 2026 E ← (facing south: left=east, right=west) → W CEILING 2.75m FLOOR D1 STC 50 90×220cm 25cm from E (LEFT) 490 cm 275 cm Bass trap SW+SE corners only D1 acoustic door STC 50
South Wall
No duct penetrations. Acoustic panel treatments per SSOT schedule.
Editing Suite — East wall B312-2 · 175×275cm · SE trap only · 1 panel · DXF verified Apr 7 2026 S ← (facing east: left=south, right=north) → N CEILING 2.75m FLOOR 1200×600 175 cm 275 cm
East Wall
No duct penetrations on this wall.
Editing Suite — West wall B312-2 · 175×275cm · SW trap only · 1 panel · DXF verified Apr 7 2026 N ← (facing west: left=north, right=south) → S CEILING 2.75m FLOOR 1200×600 175 cm 275 cm
West Wall
No duct penetrations on this wall.

Surface 5: Ceiling — Reflected Ceiling Plan RCP

Tile: Armstrong Ultima+ NRC 0.70  |  Ceiling height: 275cm AFF [AC]

IDU-03 (crossover) FA FA Run B2 (300mm sil.) 30W LED 30W LED plenum barrier at partition NORTH 175 cm 490 cm

Ceiling Build-Up (Cross-Section)

Structural slab 340cm from FFL Services zone 37 cm ducts Duct zone 25 cm Insulation Rockwool ProRox 10 cm T-grid + tile Armstrong Ultima+ NRC 0.70 5 cm Room Interior — 275 cm AFF Interior 275 cm Plenum 50cm

Surface 6: Floor Build-Up Floor

Finish: Carpet  |  Total raised floor: 15cm [AC]

Structural slab Sylomer SR28 28 kg/m3 18mm T&G ply — bottom bottom layer staggered joints (offset 400mm) 18mm T&G ply — top top layer Carpet finish 25mm PERIMETER GAP — MUST NOT BRIDGE [AC] Total build-up: 15 cm [AC]

Floor Plan View

25 mm perimeter gap (red dashed) CARPET FLOORING No floor box — workstations use wall outlets 490 cm x 175 cm

Quick Reference: All Rooms

Property VO Live Control Studio Editing
Dimensions 275–327 x 176 cm 207–275 x 225 cm 490 x 229 cm 490 x 175 cm
Ceiling Tile Rockfon Sonar E
NRC 0.90
Rockfon Sonar E
NRC 0.90
Rockfon Sonar E
NRC 0.90
Armstrong Ultima+
NRC 0.70
Floor Finish Vinyl Carpet Vinyl Carpet
IDU Assignment IDU-04 (dedicated) IDU-03 (shared) IDU-05 (dedicated) IDU-03 (crossover)
Duct Run Run A (1500mm sil.) Run B1 (500mm sil.) Run C (1000mm sil.) Run B2 (300mm sil.)
Lighting 1x 200W LED 1x 40W LED 1x 200W LED 2x 30W LED
Floor Box CR-FB ST-FB