SSOT v3.7

Acoustic Charts

Visual representations of the MediaVerse acoustic performance data. All values from SSOT v3.7.

All Charts

RT60 Comparison

Reverberation Time (RT60) target vs. achieved across all octave bands for each room.

Live

NC Curves

Noise Criteria (NC) octave band analysis — NC-12, NC-18, NC-25 curves.

Live

Modal Density

Room mode distribution 20–300 Hz for all 4 rooms. Axial modes L, W, H.

Live

STC Wall Comparison

Sound Transmission Class (STC) ratings for all 7 wall assemblies (W1–W7).

Live

Quick Reference — RT60 (Reverberation Time) Achieved

RoomTargetAchievedStatus
VO Live0.20 s0.20 s✅ Pass
Control Room0.30 s0.30 s✅ Pass
Video Studio0.25 s0.25 s✅ Pass
Editing Suite0.36 s0.36 s✅ Pass

Quick Reference — NC (Noise Criteria) Targets

RoomNC TargetHVACSilencer
VO LiveNC-12IDU-04 dedicatedRun A — 1500 mm, 40 dB, 1.5 m/s
Control RoomNC-18IDU-03 sharedRun B — 1000 mm + Run B1 — 500 mm
Video StudioNC-18IDU-05 dedicatedRun C — 1000 mm, 25 dB, 2.0 m/s
Editing SuiteNC-25IDU-03 sharedRun B — 1000 mm + Run B2 — 300 mm
[AC] Acoustic Critical — Cannot be modified without written approval from the acoustic consultant.    [HP] Hold Point — Stop work and obtain sign-off before proceeding to next phase.    [DEC] Decorative — Can be customized within the stated constraints (color, texture, finish).