Material Substitution Guide — Damascus Local

Local procurement reference for specified acoustic products and acceptable substitutions. Any performance-affecting change requires written acoustic consultant approval before order release.

Scope
Materials + hardware
Market
Damascus local supply
Approval
Written consultant review
Import Items
GG + MLV + drop seals

Substitution Table

Performance First
SpecifiedSpecDamascus substitutePerformance deltaAdjustment
Rockwool RWA45 100 mmNRC 0.95, 45 kg/m³Isover IBR 40 or local mineral wool ≥ 40 kg/m³0 to -3 dB if density is lowerAdd 25 mm thickness if density < 40 kg/m³
Rockwool ProRox SL 930NRC 0.90 ceilingMineral wool tile with NRC ≥ 0.80RT60 may increase 10–15%Add 1–2 extra wall panels if NRC is lower
Sylomer SR2828 kN/m², fn 8–12 HzGetzner Sylodyn NE or Farrat M28Equivalent if load spec is matchedVerify load rating against floor dead load before use
Tremco ACR sealantAcoustic Class ALow-modulus polyurethane acoustic sealantEquivalent if Shore A < 20Perform adhesion test before full application
Tremco Fyre-Sil2 hr fire rated + acousticHilti FS-ONE or 3M CP 25WB+Equivalent fire ratingLocal fire inspector approval required
Green Glue compoundConstrained layer dampingNo substitute existsCannot be substitutedMUST IMPORT — order 90 days before wall works
RSIC-1 clipsDecoupling resilient clipsKinetics RIM or Mason Industries0 to -2 dB STCVerify spacing per manufacturer spec
Rockfon Sonar ENRC 0.90, Class A fireArmstrong Ultima+ or Ecophon Solo NRC ≥ 0.90Equivalent if NRC matchesSame installation method
Pemko 411 drop sealAutomatic acoustic thresholdNo local substitute known. Import or Athmer 1-731N/AOrder with doors
Mass Loaded Vinyl 6 mmSTC +5 dB contributionNo substitute existsCannot be substitutedMUST IMPORT — order 60 days before door works

Must Import Items

Procurement Risk
Green Glue, MLV, and drop seals must be imported. No Damascus substitute provides equivalent performance. Order lead time: 45–90 days. All substitutions require written acoustic consultant approval.

Green Glue

Critical to W3, W4, W5, and W7 performance. Missing or substituting it reduces damping and risks STC shortfall.

Mass Loaded Vinyl

Needed in the door leaves to reach the stated door ratings. Do not replace with thin rubber, felt, or lead sheet improvisations.

Automatic Drop Seals

Acoustic thresholds require tested compression and reliable actuation. Generic door sweeps are not acceptable replacements.