SSOT v3.7 · Contractor Detail Drawing · Acoustic Design Basis
Sylomer SR28 Pad Layout Plans
Top-view pad grids for all rooms using 150 × 150 mm Sylomer pads at 400 mm centers. Every plan shows the 25 mm perimeter gap and any local keep-out zones that must remain isolated from the float floor build-up.
Pad Size
150 × 150 mm
Thickness
25 mm
Grid
400 mm centers
Load Rating
28 kN/m²
VO Live Layout
28 padsControl Room Layout
42 padsVideo Studio Layout
72 padsEditing Suite Layout
46 pads · column keep-outsSummary Table
| Room | Pad Count | Sylomer Area m² | Load Check |
|---|---|---|---|
| VO Live | 28 | 0.63 | Pass |
| Control Room | 42 | 0.95 | Pass |
| Video Studio | 72 | 1.62 | Pass |
| Editing Suite | 46 | 1.04 | Pass with column keep-outs |
| Total | 188 | 4.24 | Order 207 pads incl. 10% waste buffer |