SSOT v3.7 · Contractor Detail Drawing · Acoustic Design Basis

Sylomer SR28 Pad Layout Plans

Top-view pad grids for all rooms using 150 × 150 mm Sylomer pads at 400 mm centers. Every plan shows the 25 mm perimeter gap and any local keep-out zones that must remain isolated from the float floor build-up.

Pad Size
150 × 150 mm
Thickness
25 mm
Grid
400 mm centers
Load Rating
28 kN/m²

VO Live Layout

28 pads
Room: 275 × 176 cm Pad count: 28 Sylomer area: 0.63 m² Perimeter gap: 25 mm [AC]

Control Room Layout

42 pads
Room: 275 × 225 cm Pad count: 42 Sylomer area: 0.95 m² Perimeter gap: 25 mm [AC]

Video Studio Layout

72 pads
490 × 229 cm room footprint Pad count 72 · Sylomer area 1.62 m²

Editing Suite Layout

46 pads · column keep-outs
COL_W + 10 mm COL_E + 10 mm 490 × 175 cm room footprint Pad count 46 · Sylomer area 1.04 m² Column keep-outs remove two pad positions near COL_W and the east-edge clip zone.

Summary Table

RoomPad CountSylomer Area m²Load Check
VO Live280.63Pass
Control Room420.95Pass
Video Studio721.62Pass
Editing Suite461.04Pass with column keep-outs
Total1884.24Order 207 pads incl. 10% waste buffer