Control Room

B311 — Audio mixing and monitoring — The critical listening environment

Use Cases

Audio mixing, monitoring, quality control, client review sessions. This is where all recorded content is evaluated and mixed to final output.

Requires NC-18 and calibrated stereo monitoring with Genelec 8030C speakers at ±30°.

Room Data

ParameterValue
Room codeB311
Width (south)207 cm [AC]
Width (north)275 cm
Width (avg)241 cm
Depth225 cm
Area5.43 m²
Volume14.93 m³
Ceiling AFF275 cm (60% Rockfon cloud) (60% = 3.30 m² of 5.43 m² floor area, centered above listening position)
FlooringCarpet
NC targetNC-18
RT60 achieved0.30s
Schroeder freq283 Hz
IDUIDU-03 (shared with Editing)

Floor Plan Position

Control Room sits south of VO Live, west of the buffer spine. The south wall width is 207 cm (not 210) — this is a locked SSOT value.

Column COL_W at (369.1, 140.6) passes through this zone with a 10mm air gap maintained around it.

Room Footprint

275 cm 207 cm (south face) 225 cm D2 OW-1 Control Room B311 · 5.43 m² N

Acoustic Treatment

ElementQtySpecification
Absorption panels2 [AC]First-reflection side walls — cannot be removed or moved
Bass traps4Rockwool RWA45 150mm, floor-to-ceiling, corners
QRD diffusers2Rear wall
Ceiling60%Rockfon cloud (partial coverage)
Ceiling cloud1 [AC]200x120cm suspended cloud, centered over mix position at 245cm AFF. 50mm Rockwool RWA45 in fabric-wrapped frame. Reduces first ceiling reflections at the listening position.

Monitor Setup

ParameterValue
MonitorsGenelec 8030C L+R
Angle±30° stereo triangle
Listening position1.54m from front wall (68% depth)
38% Rule — Mix Position Geometry
Optimal listening position = 38% of room depth from speaker wall = 0.38 x 225cm = 85.5cm.
Stereo triangle: speakers at ±30° = 1.54m separation at 1.33m distance.
SBIR Warning: Side-wall proximity creates a cancellation notch near 90 Hz. The 2 first-reflection panels on side walls are mandatory to manage this.

RT60 Analysis

BandTarget (s)Achieved (s)Status
125 Hz0.400.42✓ Pass
250 Hz0.380.38✓ Pass
500 Hz0.350.34✓ Pass
1 kHz0.330.32✓ Pass
2 kHz0.330.31✓ Pass
4 kHz0.330.30✓ Pass

Room Modes

ModeFrequency
Length (L)76.2 Hz
Width (W)71.2 Hz
Height (H)62.4 Hz
Schroeder283 Hz
62.4 Hz Double Mode Warning
Room width (275cm) equals ceiling height (275cm), creating a doubled axial mode at 62.4 Hz (f = 343 / (2 x 2.75) = 62.4 Hz). This causes phantom bass buildup at the mix position. A membrane absorber tuned to ~62 Hz on the south wall is recommended to manage this resonance.
Schroeder frequency: 283 Hz — modal behavior dominates below this frequency.

Noise Criteria

Target: NC-18

Octave (Hz)631252505001k2k4k8k
NC-18 limit (dB)5444373127242221

Boundary Build-ups

WallTypeLab STCFieldAssembly
North (W6)Partition5347–51VO/Control partition (obs. window OW-1)
South perimeterConcrete6558–62300mm concrete + RSIC-1 + 50mm RW + 2×gyp
East (W5)Buffer spine5549–532×12.5mm gyp+GG + 100mm studs+RW + 2×12.5mm gyp+GG
West (W2)Diagonal concrete6558–62RSIC-V clips
CeilingRockfon cloud60% coverage, 275cm AFF
FloorFloatCarpet finish + 15cm Sylomer buildup

HVAC

ParameterValue
IDUIDU-03 (shared with Editing)
Trunk silencerRun B: 1000mm, 25dB
Branch silencerRun B1: 500mm, 15dB (Control branch)

Design Constraints [AC]

  • [AC] First-reflection panels (2 panels) — cannot be removed or moved
  • [AC] Observation window OW-1 into VO Live on north wall, sill 100cm AFF, 5° tilt
  • [AC] COL_W at (369.1, 140.6) passes through this zone — 10mm air gap maintained
  • Custom production desk (207cm room width × 160cm desk = 47cm clearance). L-shaped: main wing 160×75cm + return wing 90×60cm + raised monitor shelf +20cm. Steel frame + birch plywood. Full build spec in project documentation.